    題名: The application of capillary pumped loop for cooling of electronic components
    作者: 陳品志;Chen, Pin-Chih;Lin, Wei-Keng;(東方技術學院電機工程系)
    貢獻者: 東方技術學院電機工程系
    關鍵詞: Capillary pumped loop;Natural circulation;CPU
    日期: 2001
    上傳時間: 2010-01-11 12:33:03 (UTC+8)
    摘要: A capillary pumped loop (CPL) can be used as a heat transferring device for cooling electronic chips (such as CPU of a personal computer or notebook). The purpose of the paper is to investigate the parameters affecting the CPL. The thermal transport characteristics of CPL are obtained from experimental results. A 4.2×3.8×0.8 cm3 CPL was designed for the experiments. The results indicate that: (1) the device is capable of dissipating 40 W of thermal energy and keeping the chip surface temperature under 100°C; (2) the device can transfer heat from the evaporator to the condenser through natural circulation (i.e., without any external driving forces) if the relative height difference between the evaporator and condenser is greater than 1 cm. Some transport phenomena of the working fluid and the heat transfer characteristics of the loop were observed in the experiments and are discussed in detail below.
    關聯: Applied Thermal Engineering, Volume 21, Issue 17, December 2001, Pages 1739-1754
    顯示於類別:[電機工程系(數位科技系、玩具科)] 期刊論文

    文件中的檔案:

    沒有與此文件相關的檔案.



    在TFIR中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋